Double X Configuration Screw Fixation for Middle Phalanx Fracture - A Case Report.

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả: Mojahed Sakhnini

Ngôn ngữ: eng

Ký hiệu phân loại: 627.12 Rivers and streams

Thông tin xuất bản: India : Journal of orthopaedic case reports , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 171099

INTRODUCTION: Techniques for treating phalangeal fractures are evolving. Intramedullary screws are a trendy surgical choice that leads to optimal results. Metacarpals and proximal phalanges could tolerate two screws. We want to demonstrate that middle phalanx fractures could also be treated with double-cannulated screws. CASE REPORT: A 19-year-old patient with a middle phalanx fracture of the 4th left digit was treated with Kirschner wires leading eventually to malunion. We revised the fracture with a redo, recreating the fracture and introducing retrograde crossed-cannulated screws with excellent stability that allowed an immediate range of motion. The patient achieved union with full grip and range of motion. CONCLUSION: Middle phalanx fractures could be treated with two screws in a crossed configuration achieving stable fixation and obviating the proximal interphalangeal joint.
Tạo bộ sưu tập với mã QR

THƯ VIỆN - TRƯỜNG ĐẠI HỌC CÔNG NGHỆ TP.HCM

ĐT: (028) 36225755 | Email: tt.thuvien@hutech.edu.vn