An accelerometry-based, low cost and non-invasive respiration monitoring in anesthetized mice.

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả: Tetsuya Akagi, Natsuki Akashi, Masumi Eto, Hiroaki Kuno, Yui Miyagawa

Ngôn ngữ: eng

Ký hiệu phân loại: 297.1248 Sources of Islam

Thông tin xuất bản: Japan : The Journal of veterinary medical science , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 176394

Respiratory rate monitoring is essential especially for anesthetized animals in veterinary and biomedical research. Current methods often rely on invasive or wearable devices, which can stress animals, especially smaller ones like rodents. Here we present a non-invasive, environmentally integrated device that detects subtle breathing movements through waveform analyzed data via a triaxial accelerometer under a flexible fabric sheet in a trampoline-like box. The accuracy of the system was tested on anesthetized mice under varying isoflurane concentrations (1 to 3%) by comparison with a laser displacement sensor. The accelerometer data closely correlated with that from a laser displacement sensor, particularly under deeper anesthesia, with minimal deviations in respiratory rate detection. This method may provide a promising alternative for animal respiratory monitoring.
Tạo bộ sưu tập với mã QR

THƯ VIỆN - TRƯỜNG ĐẠI HỌC CÔNG NGHỆ TP.HCM

ĐT: (028) 36225755 | Email: tt.thuvien@hutech.edu.vn

Copyright @2024 THƯ VIỆN HUTECH