A novel minimally invasive technique for the treatment of tibial plateau collapse fracture: radiological and arthroscopic evaluation.

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả: Wen An, Chunxu Fu, Wei He, Chengsi Li, Guimiao Li, Fengkun Wang, Zhongzheng Wang, Shuai Yang, Yanjiang Yang, Yingze Zhang, Yanbin Zhu

Ngôn ngữ: eng

Ký hiệu phân loại:

Thông tin xuất bản: Germany : International orthopaedics , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 180563

PURPOSE: To examine the effectiveness of a novel bone graft reduction technique with a bone tamp impactor instrument in minimally invasive treatment of tibial plateau collapse fractures through arthroscopic and imaging evaluation. METHODS: This is a retrospective analysis of prospectively collected data on patients with tibial plateau collapse fracture who received the novel bone graft reduction procedure with a bone tamp impactor instrument for minimally invasive treatment of tibial plateau collapse fractures in a tertiary referral university hospital from February 2021 to March 2023. Patients were classified according to a classification combined with Schatzker classification, AO classification and three-column classification. Arthroscopy evaluation and radiographs were used to measure the reduction effect. RESULTS: A total of 196 patients were eligible and included. Compared to the preoperative values, post-ADD(c) showed a significant reduction improvement (P = 0.000-0.007), ranging from 87.9 to 96.6% for different classifications. The post-ADD (s) have decreased by 87-96.8% (P = 0.000-0.039), the post-FFG and post-TPW reduced by 87.5-100% (P = 0.000-0.026) and 34.2-63.5% (P = 0.000-0.075) respectively. Additionally, the lower limb alignment have been significantly corrected, with notable changes in post-MPTA (P = 0.000-0.081), post-PTSA (P = 0.000-0.178) and post-FTA (P = 0.000-0.069) for different types of fracture, measured one day after surgery. Arthroscopic evaluation indicated that the average articular surface depression depth was less than 4 mm, and over 60% achieved a depression depth of less than 2 mm. All patient achieved a less than 2 mm of postoperative fracture fragment gap, with over 50% achieving a gap of less than 1 mm. None of patients experienced neurovascular injury or wound infection. CONCLUSION: The novel bone graft reduction technique utilizing a bone tamp impactor instrument can achieve effective reduction in all types of tibial plateau collapse fractures. This method may prove to be a useful option for minimally invasive treatment of tibial plateau fractures.
Tạo bộ sưu tập với mã QR

THƯ VIỆN - TRƯỜNG ĐẠI HỌC CÔNG NGHỆ TP.HCM

ĐT: (028) 36225755 | Email: tt.thuvien@hutech.edu.vn

Copyright @2024 THƯ VIỆN HUTECH