Comparative study of peripheral intravenous catheter insertions with capillary, notched, and a grooved needle flashback design.

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả: Lois Kaufman, Nancy Moureau

Ngôn ngữ: eng

Ký hiệu phân loại: 627.12 Rivers and streams

Thông tin xuất bản: United States : The journal of vascular access , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 184270

Evidence of the costly effects of first-attempt peripheral intravenous catheter (PIVC) insertion failures continues to mount. This study was conducted to determine if a unique catheter design can improve operative error, promote PIVC first-stick success and reduce the costs of first-attempt failures. In Phase One of this comparative simulation use in vitro study, 16 nurses from acute care hospitals inserted four PIVC types into a training model, each type characterized by distinct timing of flashback occurrence and needle design. Each nurse performed three attempts per catheter type (12 total per inserter). Insertions were video-recorded and analyzed for the effect of the needle on a vessel during insertion, double punctures and catheter placement failure or success. In Phase Two, 100 nurses and 25 purchasing agents nationwide identified items used and associated costs for PIVC insertions. In Phase One, nurses using a grooved needle flashback with a thin-tipped needle were 20% more successful with catheter placement than those using a notched needle flashback and 22% more successful than those placing a capillary flashback design. Catheter placement success with a grooved needle flashback was 15% higher than with a capillary flashback and 13% higher than with a notched needle flashback. Double punctures were highest among nurses using a capillary flashback catheter, and catheter placement failure was highest among nurses using notched needle flashback. In Phase Two, nurses reported an average of 51% first-attempt success. The authors calculated the estimated annual cost of first-stick failure to be S 35,919.15 per nurse, including labor and materials used in the second and third attempts. In this study, the authors found the insertion technique with grooved flashback needle design reduced operative error, double punctures and improved first-attempt success. This flashback needle design could significantly improve patient outcomes, speed time to treatment and reduce hospital costs.
Tạo bộ sưu tập với mã QR

THƯ VIỆN - TRƯỜNG ĐẠI HỌC CÔNG NGHỆ TP.HCM

ĐT: (028) 36225755 | Email: tt.thuvien@hutech.edu.vn

Copyright @2024 THƯ VIỆN HUTECH