Patient Reported Outcomes of Total Knee Arthroplasty with Ultra-congruent Lipped Polyethylene Liners: A Randomized Study.

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả: Valentin Antoci, Thomas J Barrett, Drew Clippert, Mohammad Daher, Zainab Ibrahim, Jacob Laperche, Jonathan Liu

Ngôn ngữ: eng

Ký hiệu phân loại: 003.209 Historical, geographic, persons treatment of forecasting as a discipline

Thông tin xuất bản: Iran : The archives of bone and joint surgery , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 237378

 OBJECTIVES: The purpose of this study is to compare the Depuy curved (CVD) polyethylene insert to the curved plus (CVD+) design in TKA, which has an increased dished curve for increased articulation congruence and thus secondary anterior to posterior stability. METHODS: A randomized controlled trial with 100 patients was conducted to compare two knee replacement designs (CVD and CVD+ polyethylene inserts) using the Johnson and Johnson DePuy PFC Sigma total knee replacement. All participants, were randomized and blinded to reduce bias. The trial achieved 100% recruitment and maintained blinding throughout the study. Demographics, baseline characteristics, and KOOS scores were recorded pre-operatively, and at 3 and 12 months postoperatively. In addition, physical and mental component scores (PCS and MCS) were collected at 12 months post-operatively. RESULTS: Sixty patients had preoperative data, split equally into CVD and CVD+ groups. The cohort's average age was 71.47 years, and 72% were female, with no statistically significant demographic differences between groups. Preoperative measures showed no differences in Pain, ADL, or QOL. At 3 months, no significant differences were noted, though the QOL difference was 64.45 ± 16.57 for CVD and 52.94 ± 27.1 for CVD+ (p = 0.15). At 12 months, trends favored the CVD group, but differences in Pain, ADL, QOL, PCS, and MCS were not significant. Complications were similar, except for stiffness, with 0 cases in the CVD group and 3 in the CVD+ group at 3 months
  both had 2 additional cases at 12 months. CONCLUSION: In our study, there was no difference between designs in terms of pain, activities of daily living, and standard outcomes. Further studies are required to support the benefit of increased congruence in the CVD+ design, even though widespread adoption has been common across the industry.
Tạo bộ sưu tập với mã QR

THƯ VIỆN - TRƯỜNG ĐẠI HỌC CÔNG NGHỆ TP.HCM

ĐT: (028) 36225755 | Email: tt.thuvien@hutech.edu.vn

Copyright @2024 THƯ VIỆN HUTECH