Sequences B, C, and D: Downwind Baseline (F), Downwind Low Pitch (F), Downwind High Pitch (F) This test sequence used a downwind, teetered turbine with a 3.4� cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of �180� were achieved at low wind speeds, and yaw angles of -20� to 10� were achieved for high wind speeds. The blade tip pitch was 3� for sequence B, 0� for sequence C, and 6� for sequence D. These three sequences were interleaved during testing because the pitch angle change was easily made by the turbine operator. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected.