: Bismuth film electrode prepared in situ on glassy carbon disk surface (abbreviated to BiFE in situ) was used as working electrode for Differential Pulse Anodic Stripping Voltammetry (DP-ASV) for the determination of copper (Cu) in acetate buffer (pH = 5). The influence of the factors on Cu stripping peak curents (Ip) such as: BiIII concentration, pH, deposition potential and deposition time, the electrode rotating speed, interferents,… were investigated. At the deposition potential of -1400 mV, the deposition time of 120 s and other appropriate experimental conditions, the method gained high sensitivity (0.35 ± 0.01 μA/ppb), good repeability of the Ip : RSD = 2.8 % (n = 8), low detection limit (3s) was (1.4 ppb)
linear correlation between the Ip and the Cu concentration was good in the range of 2.5 – 25 ppb (R ≥ 0.998). This method was successfully applied to the determination of Cu in river-water samples at Quang Binh province.Điện cực màng bismut được tạo ra theo kiểu in situ trên nền đĩa rắn than thủy tinh (viết tắt là BiFE in situ) được dùng cho phương pháp von-ampe hòa tan anot xung vi phân (DP-ASV) để xác định đồng (Cu) trong nền đệm axetat (pH = 5). Các yếu tố ảnh hưởng đến dòng đỉnh hòa tan (Ip) của Cu như: nồng độ BiIII, pH, thế và thời gian điện phân làm giàu, tốc độ quay điện cực, các chất cản trở cũng được khảo sát. Ở thế điện phân làm giàu -1400 mV, thời gian điện phân làm giàu 120 s và các điều kiện thí nghiệm khác thích hợp, phương pháp đạt được độ nhạy cao (0,35 ± 0,01 μA/ppb), độ lặp lại tốt của Ip : RSD = 2,8 % (n = 8), giới hạn phát hiện (3s) thấp (1,4 ppb)
giữa Ip và nồng độ Cu có tương quan tuyến tính tốt trong khoảng 2,5 đến 25 ppb với R ≥ 0,998. Phương pháp đã được áp dụng thành công để xác định Cu trong các mẫu nước sông ở tỉnh Quảng Bình