The application of MMC converters to power systems has many advantages such as: operation at high voltage, large capacity. The problem of MMC when applying NLM modulation is to balance the voltage on the capacitors to ensure stable operation of the MMC. This paper proposes a voltage balance algorithm on the capacitor by arranging the capacitor voltage value to select the ON and OFF of the SMs. The algorithm is implemented by program the arrangement of the capacitor voltage value measure from the sensors to select the appropriate SMs to be turned on in a modulation cycle in order to ensure the capacitor voltage balance between the SMs. The algorithm is applied to the MMC model with 13 AC voltage levels and is verified by simulation on Simulink software and system experiments to prove that the algorithm implementation is feasible.Việc áp dụng bộ biến đổi đa mức MMC (Modular Mutilevel Converter) cho các hệ thống điện có nhiều ưu điểm như: hoạt động ở điện áp cao, công suất lớn. Vấn đề của MMC khi áp dụng điều chế NLM (Nearest Level Modulation) là cân bằng điện áp trên các tụ điện nhằm đảm bảo sự hoạt động ổn định của MMC để giảm được tần số chuyển mạch của IGBT. Bài báo đề xuất thuật toán cân bằng điện áp trên tụ điện bằng cách sắp xếp giá trị điện áp tụ điện để lựa chọn đóng mở các SM (Sub-Module). Thuật toán được thực hiện bằng cách lập trình sắp xếp giá trị điện áp tụ đo về từ các cảm biến để chọn lựa các SM phù hợp được bật trong một chu kỳ điều chế nhằm mục đích đảm bảo cân bằng điện áp tụ giữa các SM. Thuật toán được áp dụng cho mô hình MMC có 13 mức điện áp xoay chiều và được kiểm chứng bằng mô phỏng trên phần mềm Simulink, thực nghiệm hệ thống ở quy mô phòng thí nghiệm để chứng minh thực hiện thuật toán là khả thi.