Currently, renewable energy sources integrated into Vietnam's medium-voltage power grid are developing strongly nationwide. Operational reality shows that the integration of renewable energy sources into the distribution grid is causing power quality problems such as overvoltage, increased capacity loss on the grid, and especially negative impacts on power quality to the working of the protective relay system. This article analyzes and evaluates the impact of the Yen Dinh solar power plant in Thanh Hoa, Vietnam when connected to the 22kV power grid such as: reverse power flow, overvoltage, influence of harmonics, changes operational methods for placing economic capacitors and coordinating protection when the plant is connected to the distribution grid are also calculated and analyzed. The research results are based on the connection standards of the distribution grid and use ETAP software for simulation. The results are analyzed, evaluated show that the applicability of this research in practice.Hiện nay, các nguồn năng lượng mới và tái tạo tích hợp vào lưới điện trung áp của Việt Nam đang phát triển mạnh trên phạm vi toàn quốc. Thực tế vận hành cho thấy, việc tích hợp các nguồn năng lượng tái tạo vào lưới điện phân phối đang gây nên những vấn đề về chất lượng điện năng như quá điện áp, gia tăng tổn thất công suất trên lưới và đặc biệt là ảnh hưởng tới sự làm việc của hệ thống rơ le bảo vệ. Bài báo này, phân tích đánh giá tác động của Nhà máy điện mặt trời Yên Định tại Thanh Hóa, Việt Nam khi kết nối vào lưới điện 22kV như: trào lưu công suất ngược, quá điện áp, ảnh hưởng sóng hài, thay đổi phương thức vận hành đặt tụ bù kinh tế và phối hợp bảo vệ khi nhà máy kết nối với lưới điện phân phối cũng được tính toán và phân tích. Các kết quả nghiên cứu dựa trên các tiêu chuẩn đấu nối của lưới điện phân phối và sử dụng phần mềm ETAP để mô phỏng. Các kết quả được phân tích, đánh giá cho thấy khả năng ứng dụng của nghiên cứu trong thực tế.