An enhanced nonlinear control technique based on a coordination between feedback linearization (FBL) approach and sliding mode control (SMC) is proposed for a three-phase split-capacitor inverter under the nonlinear load conditions. A nonlinear model of system with pulse-width modulation (PWM) voltage-source inverter (VSI) including the output inductor-capacitor (LC) filters is derived in the d-q-0 synchronous reference frame, not by small signal analysis. The controllers for d-q-0 components of three-phase line-to-neutral load voltages are designed by linear control theory. With the proposed coordination scheme, three-phase split-capacitor inverter provides an excellent control performance for regulating the load voltages with nearly zero steady-state errors in both the transient and steady states. The proposed scheme is verified by the simulation results which show that three-phase split-capacitor inverter gives a low total harmonic distortion (THD) for the load voltages under the balanced or unbalanced nonlinear load conditions.Kỹ thuật điều khiển phi tuyến nâng cao dựa trên sự phối hợp giữa kỹ thuật tuyến tính hóa hồi tiếp (FBL) và điều khiển trượt (SMC) được đề xuất cho bộ nghịch lưu chia tụ ba pha trong trường hợp tải phi tuyến. Mô hình phi tuyến của hệ thống với bộ nghịch lưu nguồn điện áp điều chế độ rộng xung (PWM) bao gồm các bộ lọc LC ở ngõ ra được hình thành trong hệ tọa độ quay (dq0), mà không cần dùng phương pháp phân tích tín hiệu nhỏ. Bộ điều khiển đối với các thành phần d-q-0 của điện áp pha của tải được thiết kế theo kỹ thuật điều khiển tuyến tính. Với chiến lược kết hợp đề xuất, bộ nghịch lưu chia tụ ba pha tạo ra vận hành điều khiển tốt để điều khiển điện áp tải với sai số gần như bằng không cả trạng thái quá độ và xác lập. Chiến lược đề xuất được kiểm chứng bởi các kết quả mô phỏng, cho thấy rằng bộ nghịch lưu chia tụ ba pha cho độ méo hài tổng (THD) thấp đối với điện áp tải trong trường hợp tải phi tuyến cân bằng và không cân bằng.