Tác giả: Ankit Agrawal, Aro Daniela Arockiam, Patrick Collier, Joseph El Dahdah, Tiffany Dong, Brian P Griffin, Richard A Grimm, Elio Haroun, Muhammad Majid, Zoran B Popovic, Leonardo Rodriguez, Sharmeen Sorathia, Tom Kai Ming Wang

Ngôn ngữ: eng

Ký hiệu phân loại: 518.6 Numerical methods in analysis

Thông tin xuất bản: United States : Echocardiography (Mount Kisco, N.Y.) , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 57586

 BACKGROUND: Left ventricular global longitudinal strain (LVGLS) by speckle-tracking transthoracic echocardiography (TTE) is an established measure of left ventricular systolic function with many clinical applications. Strain software has evolved to achieve vendor-neutrality in recent developments, although there is a notable absence of external validation studies. We assessed the normal ranges and associated factors of two-dimensional LVGLS quantification by TomTec, EchoPAC, VVI, and Epsilon contemporary strain software in a healthy cross-sectional cohort. METHODS: One hundred healthy subjects undergoing TTE during January-April 2023 at our institution were cross-sectionally recruited, 20 per age-group, 50% were female, and 50% had GE and 50% Philips scans. TomTec version 51.02 (Autostrain LV), EchoPAC version 206 (AFI-LV), VVI version (V.2.00-070730), and Epsilon (5.0.2.11295) were utilized to quantify two-dimensional LVGLS in all patients for comparative and regression analyses. RESULTS: Means and lower limits of normal (95% confidence intervals) of LVGLS were -17.1% (-17.5%, -16.7%) and -14.7% (-15.4%, -14.0%) for TomTec
  -17.8% (-18.4%, -17.2%) and -14.4% (-15.3%, -13.5%) for EchoPAC
  -16.3% (-16.9%, -15.7%) and -13.0% (-13.9%, -12.1%) for VVI
  and -17.0% (-17.6%, -16.4%) and -12.8% (-13.8%, -11.8%) for Epsilon. Factors significantly associated with LVGLS measurements in multivariable regression analyses with their beta-coefficients (95% CI) were female -1.36 (-2.12, -0.59), heart rate (per 10 bpm) with a coefficient of 0.38 (0.10-0.66), left ventricular ejection fraction (per 10%) -1.03 (-1.72, -0.34), and EchoPAC (vs. TomTec) -0.62 (-1.2, 0.0), VVI (vs. TomTec) 0.82 (0.23, 1.41) and Epsilon (vs. TomTec) 0.13 (-0.45, 0.72). CONCLUSION: LVGLS measurements were feasible across all four strain software on both GE and Philips scans in this study. Reference ranges to define normal, abnormal, and borderline LVGLS values along with associated factors in healthy patients are reported to enable clinical applications.