Comparison of AI-based retinal fluid monitoring in neovascular age-related macular degeneration with manual assessment by different eye care professionals under optimized conditions.

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả: Hrvoje Bogunovic, Wolf Bühl, Bianca S Gerendas, Felix Goldbach, Anastasiia Gruber, Oliver Leingang, Martin Michl, Georgios Mylonas, Stefan Sacu, Amir Sadeghipour, Ursula Schmidt-Erfurth

Ngôn ngữ: eng

Ký hiệu phân loại: 629.1325214 Aerospace engineering

Thông tin xuất bản: England : Acta ophthalmologica , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 57993

 PURPOSE: To investigate whether automated intra- and subretinal fluid (IRF/SRF) volume measurements are equivalent to manual evaluations by eye care professionals from different backgrounds on real-world optical coherence tomography (OCT) images in neovascular age-related macular degeneration (nAMD). METHODS: Routine OCT images (Spectralis, Heidelberg Engineering) were obtained during standard-of-care anti-VEGF treatment for nAMD at a tertiary referral centre. IRF/SRF presence and change (increase/decrease/stability) were assessed without time constraints by five retinologists, three ophthalmology residents, three general ophthalmologists, three orthoptists and three certified readers. Fluid volumes were segmented and quantified using a regulatory-approved AI-based tool (Vienna Fluid Monitor, RetInSight, Vienna, Austria). Sensitivity/specificity (Sen/Spe) for grading fluid presence and kappa agreement were calculated for each group. Their performances in distinguishing between IRF/SRF increase and decrease were assessed using AUCs. RESULTS: About 124 follow-up visit pairs of 59 eyes with active nAMD were included. Across all five groups, fluid volumes >
 5 nL were identified with values of 0.81-0.95 (Sen)/0.70-0.91 (Spe) for IRF and 0.89-0.98 (Sen)/0.74-0.90 (Spe) for SRF. Interpretations of IRF changes between -17 nL and +3 nL and SRF changes between -9.30 nL and +6.50 nL were associated with Sen >
  0.80 and Spe >
  0.87 among all groups. Agreements between the algorithm and groups in grading IRF/SRF presence ranged from κ = 0.69-0.82/0.73-0.79. The AUC for correctly classifying fluid change was >
 0.89 across all groups. CONCLUSION: Eye care professionals with different levels of clinical expertise assessed disease activity on standard OCT images with comparable accuracy. Despite optimizing the methodology and time resources, manual performance did not reach the high level of automated fluid monitoring.