A modified single-catheter approach for improving adrenal venous sampling in patients with primary aldosteronism.

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả: Jixin Hou, Sen Liu, Jindong Wan, Peijian Wang, Xinquan Wang, Qiang Xue, Peng Zhou

Ngôn ngữ: eng

Ký hiệu phân loại: 133.594 Types or schools of astrology originating in or associated with a

Thông tin xuất bản: United States : The journal of vascular access , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 581827

OBJECTIVES: Adrenal vein sampling (AVS) is an established procedure for assessing subtype patients with primary aldosteronism (PA). However, it is technically challenging, with high failure rates, which limits its application in clinical practice. Our study aimed to evaluate the safety and efficacy of a single-catheter modified approach for AVS. METHODS: The clinical, angiographic, and procedural data of 182 consecutive patients who underwent AVS procedures between May 2020 and May 2023 were collected and analyzed. The single-catheter modified approach was performed as a single 5 F Tiger catheter with only one-time manual reshaping, which was recommended for sequential bilateral adrenal cannulations. RESULTS: Of the 182 consecutive patients, 174 (95.6%) had successful bilateral adrenal cannulation. The single-catheter modified approach was successfully performed to cannulate the right adrenal vein in 176 (96.7%) patients, while another six (3.3%) patients needed at least a second manual reshaping for 5 F Tiger catheters. For left adrenal cannulation, a single-catheter modified approach was successfully used in 179 (98.4%) patients, whereas 5 F Tiger catheters with at least second-time manual reshaping were used in the remaining three (1.6%) patients. The procedural period was 15.6 ± 10.8 min, the fluoroscopy time was 4.2 ± 1.5 min, and the diagnostic contrast was 15.5 ± 4.8 mL. The incidence of procedure-related complications associated with AVS was 1.1%. The cumulative summation assessment illustrated that the learning curve for the operating procedure required up to 29 cases, indicating that the procedure time was shortened after 29 cases. CONCLUSIONS: The single-catheter modified approach is an effective, safe, and feasible technique for AVS treatment. In particular, this improved method is not difficult for beginners with high technical success rates.
Tạo bộ sưu tập với mã QR

THƯ VIỆN - TRƯỜNG ĐẠI HỌC CÔNG NGHỆ TP.HCM

ĐT: (028) 36225755 | Email: tt.thuvien@hutech.edu.vn

Copyright @2024 THƯ VIỆN HUTECH