BACKGROUND: Maximal treadmill cardiopulmonary exercise testing is the gold standard for assessing functional capacity in patients with idiopathic pulmonary fibrosis (IPF). PURPOSE: Primarily to investigate the concurrent validity between three field tests and cardiopulmonary exercise testing in these patients. METHODS: Patients performed the cardiopulmonary exercise testing, a six-minute walk test, an incremental shuttle walk test, and, the Glittre-ADL test. For cardiopulmonary exercise testing, the ten seconds with the higher average of the peak oxygen uptake obtained within the last 30 seconds were considered
for six-minute walk test and incremental shuttle walk test, the longer distance
and for the Glittre-ADL test, the shorter time spent. Concurrent validity was assessed using different regression models based on the best adjustment of the data. RESULTS: Twenty-two patients with IPF were assessed, aged: 68 ± 8.1 years, 13 male. Patients presented a peak oxygen uptake of 16.5 ± 3.6 mL.kg CONCLUSION: The six-minute walk test, incremental shuttle walk test, and Glittre-ADL test were considered valid tests to explain the peak oxygen uptake variance obtained by the cardiopulmonary exercise testing in patients with IPF.