Subacromial balloon spacer improves isokinetic performance in patients with massive irreparable rotator cuff tear.

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả: Emilio Calvo, Cristina Delgado, Gonzalo Luengo-Alonso, Natalia Martínez-Catalán, Almudena Fernández-Brazo Rueda, María Valencia

Ngôn ngữ: eng

Ký hiệu phân loại: 133.5262 Astrology

Thông tin xuất bản: Germany : Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 582097

 PURPOSE: The aim of this study was to analyse clinical, functional and shoulder kinematics results using subacromial balloon spacer in nonreparable massive rotator cuff tears. Subacromial balloon spacer was hypothesised to improve shoulder kinematics and increases clinical and functional outcomes scores in nonreparable massive rotator cuff tears. METHODS: This is a prospective study in massive rotator cuff tears. From October 2021 to October 2022, a total of 127 shoulders suffering massive rotator cuff tears were initially evaluated. All patients were evaluated preoperatively, at 6 and 12 months. Patients' patient-reported outcome measures (PROM) subjective values using visual analogue scale (VAS) and the Spanish Western Ontario Rotator Cuff Index (WORC) version were analysed. We also evaluated objective outcomes: constant score, range of movement and kinematic shoulder analysis (isokinetic test to evaluate internal and external rotation forces). Statistical analysis was conducted using SPSS software
  continuous variables were presented as means and standard deviations (SDs). RESULTS: Seventeen nonrepairable massive rotator cuff tears were finally included. Three patients required reverse shoulder arthroplasty before 6 months postoperative. After 1-year follow-up, objective and subjective (PROM) outcome scores and isokinetic measurements improved in 13 patients. Preoperative VAS improved from 6.5 ± 2.1 to 2 ± 1.9 points on average at 1-year follow-up and WORC index from 1603 ± 217.3 to 699 ± 361.6. Constant score from 42.1 ± 13.1 on average and at 1-year follow-up increased to 60.8 ± 14.7. Range of movement also improved in elevation 122.2 ± 39.3 to 166.9 ± 25.8, abduction 120.3 ± 38.6 to 134.6 ± 21.1, external rotation 30.3 ± 19.7 to 86.1 ± 13.8 and internal rotation L4-T12 on average at 1-year follow-up. Isokinetic evaluation showed functional improvement 1 year after implantation. Both internal and external rotation improved compared with their healthy shoulder. External rotation improved from 30.3° ± 19.7° preoperatively to 86.1° ± 13.8° (43.7% in the isokinetic study) and internal rotation from L4 preoperatively to L1 (49.8% in isokinetic study) on average. CONCLUSION: Among the different alternatives for irreparable rotator cuff injuries surgical treatment, subacromial balloon spacer is an effective alternative in selected patients, both in terms of clinical-functional improvement and short-term isokinetic results. LEVEL OF EVIDENCE: Level II.
Tạo bộ sưu tập với mã QR

THƯ VIỆN - TRƯỜNG ĐẠI HỌC CÔNG NGHỆ TP.HCM

ĐT: (028) 36225755 | Email: tt.thuvien@hutech.edu.vn

Copyright @2024 THƯ VIỆN HUTECH