The study was carried out on leucocyte and thrombocyte poor red cells product with additive solution SAGM, triple blood bag (350ml) made in JMS Singapore aimed to assess biochemical and hematological indicator of the parked red cell. The result is following: Hematological and biochemical indicator in a points such as the first day, the fourteen day, the twelty eight day, the thirty five day and fourty two day in stored
Red blood cell is reduced, hematocrite, mean corpuscular volume and hemoglobin free increase through time stored but in normal range
Ion postasium and LDH increase, ion Natri and Glucose blood reduced through time stored but in normal range.