Comparison of structure-function correlation among IMO visual function analyser and Humphrey field analyser.

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả: Dolly Chang, Chen Chen, Sofia De Arrigunaga, Tobias Elze, Sandra E Freeman, David S Friedman, Joyce Kang, Julia Anne Kim, Yihao Li, Michael M Lin, Rafaella Nascimento E Silva, Yan Zhao

Ngôn ngữ: eng

Ký hiệu phân loại:

Thông tin xuất bản: England : The British journal of ophthalmology , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 708734

 PURPOSE: To compare the structure-function correlations between optical coherence tomography (OCT) thickness parameters and the corresponding sectorial mean sensitivity (MS) values obtained with IMO visual function analyser (IMOvifa) and Humphrey field analyser (HFA) perimeters. DESIGN: Prospective cross-sectional study. METHODS: Glaucoma suspect, glaucoma and ocular hypertension patients underwent IMOvifa 24-2 Ambient Interactive Zippy Estimated Sequential Testing, HFA 24-2 Swedish Interactive Threshold Algorithm-Standard and OCT tests within 12 weeks. Based on the Garway-Heath map, the sensitivity points were divided in corresponding OCT peripapillary retinal nerve fibre layer (pRNFL) sectors, and also the central 10° points in corresponding ganglion cell-inner plexiform layer thickness over the macula. The structure-function correlations were analysed by Spearman's rank coefficient and compared by Steiger's test. RESULTS: 57 eyes of 57 patients (mean age 59.2 years, 61.4% female) with reliable field and adequate OCT strength were included in this analysis. IMOvifa had significantly shorter testing time (3.7 vs 5.3 mins), lower mean deviation (difference -0.6 dB) and greater visual field index (difference +1.0%) compared with HFA (p<
 0.001 for all). There was moderate to strong correlation between IMOvifa and HFA MS sectors (p<
 0.001 for all). IMOvifa had significant correlations in the inferior (I, r=0.46), superior (S, r=0.45), temporal (T, r=0.28) pRNFL sectors and in the I (r=0.63) and S (r=0.53) mGCPIPL hemispheres (p≤0.03 for all). There was no significant difference in the strength of the correlation of IMOvifa versus HFA results with OCT parameters (p≥0.06). CONCLUSIONS: The IMOvifa test took less time and resulted in slightly less severe defects than HFA. MS in all sectors was moderately to strongly correlated. Function-structure correlations were similar when using either perimeter.
Tạo bộ sưu tập với mã QR

THƯ VIỆN - TRƯỜNG ĐẠI HỌC CÔNG NGHỆ TP.HCM

ĐT: (028) 36225755 | Email: tt.thuvien@hutech.edu.vn

Copyright @2024 THƯ VIỆN HUTECH