Performance of ultrasound-guided attenuation parameter and 2D shear wave elastography in patients with metabolic dysfunction-associated steatotic liver disease.

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả: Francesco Agnello, Tommaso Vincenzo Bartolotta, Daniela Cabibi, Roberto Cannella, Giuseppe Infantino, Grazia Pennisi, Salvatore Petta, Giorgia Porrello, Alessandro Umberto Spinello

Ngôn ngữ: eng

Ký hiệu phân loại: 809.008 History and description with respect to kinds of persons

Thông tin xuất bản: Germany : European radiology , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 715441

 PURPOSE: To assess the performance and the reproducibility of ultrasound-guided attenuation parameter (UGAP) and two-dimensional shear wave elastography (2D-SWE) in patients with biopsy-proven metabolic dysfunction-associated steatotic liver disease (MASLD). METHODS: This study included consecutive adult patients with MASLD who underwent ultrasound with UGAP, 2D-SWE and percutaneous liver biopsy. The median values of 12 consecutive UGAP measurements were acquired by two independent radiologists (R1 and R2). Hepatic steatosis was graded by liver biopsy as: (0) <
  5%
  (1) 5-33%
  (2) >
  33-66%
  (3) >
  66%. Areas under the curve (AUCs) were calculated to determine the diagnostic performance. Inter- and intra-observer reliability was assessed with intraclass correlation coefficient (ICC). RESULTS: A hundred patients (median age 55.0 years old) with MASLD were prospectively enrolled. At histopathology, 70 and 42 patients had grade ≥ 2 and 3 steatosis, respectively. Median UGAP was 0.78 dB/cm/MHz (IQR/Med: 5.55%). For the diagnosis of grade ≥ 2 steatosis, the AUCs of UGAP were 0.828 (95% CI: 0.739, 0.896) for R1 and 0.779 (95% CI: 0.685, 0.856) for R2. The inter- and intra-operator reliability of UGAP were excellent, with an ICC of 0.92 (95% CI: 0.87-0.95) and 0.95 (95% CI: 0.92-0.96), respectively. The median liver stiffness was 6.76 kPa (IQR/Med: 16.30%). For the diagnosis of advanced fibrosis, 2D-SWE had an AUC of 0.862 (95% CI: 0.757, 0.934), and the optimal cutoff value was >
  6.75 kPa with a sensitivity of 80.6% and a specificity of 75.7%. CONCLUSION: UGAP and 2D-SWE provide a good performance for the staging of steatosis and fibrosis in patients with MASLD with an excellent intra-operator reliability of UGAP. KEY POINTS: Question How well do ultrasound-guided attenuation parameter (UGAP) and two-dimensional shear wave elastography (2D-SWE) perform for quantifying hepatic steatosis and fibrosis? Findings UGAP had a maximum AUC of 0.828 for the diagnosis of grade ≥ 2 steatosis, and 2D-SWE had an AUC of 0.862 for diagnosing advanced fibrosis. Clinical relevance UGAP and 2D-SWE allow rapid, reproducible, and accurate quantification of hepatic steatosis and fibrosis that can be used for the noninvasive assessment of patients with metabolic dysfunction-associated steatotic liver disease.
Tạo bộ sưu tập với mã QR

THƯ VIỆN - TRƯỜNG ĐẠI HỌC CÔNG NGHỆ TP.HCM

ĐT: (028) 36225755 | Email: tt.thuvien@hutech.edu.vn

Copyright @2024 THƯ VIỆN HUTECH