Regional Lymph Node Delineation variability and its Dosimetric Impact in Breast Cancer Radiotherapy.

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả: J Bliss, A M Brunt, A Caraman, P Diez, J Haviland, M Maclennan, D Megias, R Mir, Z Nabi, E Spezi, M A Sydenham, Y Tsang, D Wheatley

Ngôn ngữ: eng

Ký hiệu phân loại: 020.623 Regional, state, provincial organizations

Thông tin xuất bản: England : Clinical oncology (Royal College of Radiologists (Great Britain)) , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 743542

AIMS: To quantify the interobserver variability of regional lymph node delineation for breast cancer radiotherapy (RT) and establish whether a relationship exists between contouring variations and dosimetry using the FAST-Forward (FF) pre-trial RT quality assurance (QA) benchmark cases. MATERIALS AND METHODS: As part of the pre-trial RT QA, local site principal investigators (PIs) were asked to complete a single outlining QA benchmark case involving the delineation of axillary lymph node clinical target volumes (LNCTVs) levels 1-4. These contours were evaluated for concordance against an expert defined consensus gold standard (GS) volume using various conformity indices (CIs): discordance index (DI), geographical miss index (GMI), Jaccard index (JCI), mean distance to conformity (MDC) for both over- and under- contouring. Descriptive statistics including interquartile range (IQR) was used to evaluate interobserver variation. Wilcoxon signed-rank tests were used to establish if there were any statistically significant differences in the dosimetric parameters between plans conforming to GS volume and the volumes from the individual PI. RESULTS: Pre-trial outlining QA benchmark cases from 29/33 PIs were assessed. The median submitted LNCTV volume was 131.4 cc (IQR: 112.4 - 145.3) compared with the GS volume of 105.46 cc. For conformity indices, the median DI was 0.37 (IQR: 0.31 - 0.40), the median GMI was 0.21 (IQR: 0.13 - 0.28), the median JCI was 0.53 (IQR: 0.49 - 0.56), MDC CONCLUSION: Analysis of the FF pre-trial QA outlining benchmark case highlights the interobserver variation that exists in axillary nodal CTV (levels 1-4) delineation. Conformity indices demonstrated moderate agreement with a median Jaccard conformity index of 0.53, with both under- and over-contouring observed. All QA submissions achieved the mandatory planning dose constraints but not all optimal dose objectives of the FF trial despite the interobserver variation in target volume contouring.
Tạo bộ sưu tập với mã QR

THƯ VIỆN - TRƯỜNG ĐẠI HỌC CÔNG NGHỆ TP.HCM

ĐT: (028) 36225755 | Email: tt.thuvien@hutech.edu.vn

Copyright @2024 THƯ VIỆN HUTECH