Postmortem Diagnosis of Rabies in Animals by the Updated, Multiplexed LN34 Real-Time Reverse Transcription-Polymerase Chain Reaction Assay.

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả: Rene Edgar Condori, Crystal M Gigante, Yu Li, Vaughn Wicker, Kimberly Wilkins

Ngôn ngữ: eng

Ký hiệu phân loại: 153.154 Transfer of learning

Thông tin xuất bản: United States : Journal of visualized experiments : JoVE , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 747601

 Rabies is a fatal zoonotic disease caused by Lyssavirus rabies (RABV) and related negative strand RNA viruses from the Lyssavirus genus (family Rhabdoviridae). The LN34 assay targets the highly conserved leader region and nucleoprotein gene of the lyssavirus genome and utilizes degenerate primers and a TaqMan probe containing locked nucleotides to detect RNA across the diverse Lyssavirus genus. A negative finding for rabies should be made only if a full cross-section of the brain stem and three lobes of the cerebellum are examined
  however, identification of lyssavirus RNA in any tissue is diagnostic of rabies infection. Tissue is collected and homogenized in TRIzol reagent, which also inactivates the virus. RNA extraction is performed using a spin column-based commercial extraction kit. Master mixes are prepared in a clean space and aliquoted into a 96 well plate before adding sample RNA. In clinical settings, each sample is tested by real-time RT-PCR for the presence of lyssavirus RNA in triplicate and singly for host β -actin mRNA. Positive and negative controls are included at extraction and real-time RT-PCR steps of the protocol. Data analysis involves manual adjustment of the thresholds to standardize Ct values across instrument runs. Positive results are determined by the presence of typical amplification in the pan-lyssavirus assay (Ct ≤ 35). Negative results are determined by the absence of typical amplification in the pan-lyssavirus assay and detection of host β-actin mRNA (Ct ≤ 33). Observation of values outside of these ranges or failure of the assay controls can invalidate the run or result in inconclusive results for a specimen. The protocol should be closely followed to ensure high assay sensitivity and specificity. Procedural modifications can affect assay performance and lead to false positive, false negative, or uninterpretable results.
Tạo bộ sưu tập với mã QR

THƯ VIỆN - TRƯỜNG ĐẠI HỌC CÔNG NGHỆ TP.HCM

ĐT: (028) 36225755 | Email: tt.thuvien@hutech.edu.vn

Copyright @2024 THƯ VIỆN HUTECH