Edge-to-edge repair with ring annuloplasty for post-transplant biopsy-related tricuspid regurgitation.

 0 Người đánh giá. Xếp hạng trung bình 0

Tác giả: Corazon de la Pena, Suguru Ohira, Sooyun Caroline Tavolacci

Ngôn ngữ: eng

Ký hiệu phân loại:

Thông tin xuất bản: England : Multimedia manual of cardiothoracic surgery : MMCTS , 2025

Mô tả vật lý:

Bộ sưu tập: NCBI

ID: 9467

We experienced an early biopsy-related tricuspid regurgitation post-transplant. Transthoracic and transoesophageal echocardiography showed a frail anterior leaflet with a possible ruptured chorda. The tricuspid valve was inspected, and a ruptured chorda was noted in the anterior leaflet with a single torn chorda on the septal leaflet. The corresponding papillary muscle was difficult to identify. The patient underwent successful tricuspid valve repair with edge-to-edge repair and ring annuloplasty. Compared to a complex repair procedure such as the replacement of multiple artificial chordae, the edge-to-edge repair to correct prolapse without creating a gradient across the valve is reproducible.